Cathodic protection monitoring system
Monitoring system composition
For offshore platforms
◆ Steel structure surface electricity
→Evaluate the corrosion protection status of steel structure
◆ Sacrificial anode current
→Evaluate the consumption rate, residual life and warning polarity reversal of sacrificial anode
◆ Current density of steel structure
→Evaluate the corrosion protection status of steel shell
◆ Data acquisition, storage and analysis equipment
→Multi-terminal remote access, central control centralized control, onshore remote control, technical experts can provide remote diagnosis
Principle
Sacrificial anode current monitoring
Probe form - applicable to offshore platforms
▎System technical indicators
Steel structure surface potential monitoring
Principle
Schematic diagram of steel structure surface potential monitoring system
Objective
◆ The surface potential of steel structure is an important indicator to judge the cathodic protection status of steel structure.
Working principle
◆ The reference electrode is arranged at different positions of the steel structure to monitor the surface potential at typical positions;
◆ The potential signal collected by each reference machine is transmitted to the CP monitor, and the data is stored, transmitted and analyzed;
◆ The potential data measured by the monitor is transmitted to the main control computer through RS485 communication bus;
◆ The computer processes the potential data of each monitoring point, displays the potential measurement curve, and saves the potential data in the database.
▎Reference electrode for jacket platform
▎Technical indicators of composite reference electrode
Cathodic protection monitoring and evaluation system based on multi-data fusion
▎Software advantages and functions
Working principle
◆ Real-time monitoring and display of steel structure potential/current density, sacrificial anode current, residual life of sacrificial anode and other parameters;
◆ Realize three-dimensional visualization of protection status, and display under-protection and over-protection areas in real time;
◆ When the cathodic protection status of the steel structure is fed back, it can be used as the input signal of the ICCP system to adjust the output of the auxiliary anode current in a closed loop, so that the monitoring and control of the ICCP system can form a closed loop.
◆ Data acquisition, analysis, fault alarm, over/under protection warning and other highly automated;
◆ It has the function of querying and analyzing historical data and logs, customizing and filtering data, and automatically generating formatted reports and reports;
◆ Multi-terminal remote access, central control centralized control, onshore remote control, technical experts can provide remote diagnosis.
Address: Tangli Industrial Park, Hongqi Street, Ganjingzi District, Dalian